Hydrotest and Nitrogen Leak Test Support for Bolted Joints
When bolting and testing are run by different contractors, a weeping joint at test turns into a lost day and an argument about whose fault it is.
BoltUp Services provides hydrotest and nitrogen leak test support so bolt-up and testing run as one plan. A bolt-up is not finished until the system proves tight. Because BoltUp Services is part of the same family of companies as HydroTech Testing and NitroTech Rentals, we can plan bolting and testing together, when your project supports it.
- Over 10 years in the field through HydroTech Testing
- Recent bolt-up on an LNG vessel built in Philadelphia
- Hydro and nitrogen testing in-house through our sister companies
- Crews coast to coast across the USA, plus the UAE and Japan
Hydrostatic testing through HydroTech Testing
Hydrostatic testing fills a system with water and raises it to a specified test pressure to confirm strength and tightness. HydroTech Testing brings over 10 years of hydrostatic testing experience. When we coordinate the work:
- Test boundaries and blinds are planned with the joint register
- Temporary test closures are made up to the same standard as permanent joints
- If a joint weeps, the bolting crew is already familiar with it and can re-make it quickly
- Drain-down and restoration of test blinds are tracked so nothing is left behind
Nitrogen supply and leak testing through NitroTech Rentals
Some systems should not see water, such as LNG and fuel gas lines, cryogenic piping, instrument and some hydraulic systems, or must be tested with gas for other reasons. NitroTech Rentals supplies nitrogen and equipment for leak testing, purging and inerting. Gas testing requires careful planning because of stored energy, and is performed only under an approved procedure and exclusion zone.
Want these joints made up right the first time? Send the joint list and test date, or call Henry Froats Jr., Director.
Choosing the right test
The test medium, pressure and hold time come from the governing code, class rules, owner specification or engineer, not from us. Common considerations include:
- Whether the system can tolerate water and be fully dried afterward
- Cleanliness requirements for LNG, fuel and hydraulic service
- Strength test versus service leak test requirements
- Safety of stored energy when testing with gas
- Schedule, drainage and water disposal at the site
Hydrotest and nitrogen leak test support in one plan
When bolting and testing are run by separate contractors, a failed test can turn into a debate about whose fault it is. When they are planned together, the goal is shared: make the joints right, test once and move on.
Every Joint Documented. Nothing on Paper.
Our team uses modern AI tools to build interactive project management software for each job. Every joint, torque or tension value, gasket, inspection and test result is recorded and organized digitally, so you can find it by system, test package or joint number instead of digging through clipboards and paper tags.
- The status of every joint, visible as the work progresses
- Target values, tools, technician and date captured on each joint
- Inspection findings and test results linked to the joints they cover
- A clean, searchable turnover record when the job is done
Good records are how you know the work was done right. Ask for a demo on your project discovery call.
What to send for a fast quote
- Facility type and location
- Systems in scope and whether it is new construction, a shutdown or a retrofit
- Joint count by size and pressure class, or a line list or isometrics
- Gasket and fastener specs, plus any bolting procedure or torque tables
- Whether a hydrotest or nitrogen test follows, and the target dates
Common questions
Who performs the hydrotest?
Hydrostatic testing is performed by our sister company HydroTech Testing, with over 10 years of testing experience, planned together with the bolt-up.
Who supplies the nitrogen?
Our sister company NitroTech Rentals supplies nitrogen and equipment for leak testing, purging and inerting.
What should you do if a flange leaks during a hydrotest?
Stop and depressurize before touching the joint unless the procedure allows otherwise. Then find the cause: check bolt load, gasket and faces, correct it, re-make the joint in the proper pattern and re-test. Simply cranking down on a leaking stud often makes the joint worse.
Do flange bolts need to be retorqued?
Often, yes. Soft gaskets relax (creep) in the first hours after tightening, so many specifications call for a retorque at the final value after about 4 to 24 hours or after the first thermal cycle. Never retorque a joint that is under pressure unless the procedure specifically allows it.
Related Pages
- Data Center Chilled Water Flange Bolt-Up in Northern Virginia
- LNG Terminal Flange Bolting in Louisiana
- Compressor Station Controlled Bolting in Dallas-Fort Worth
- Request a Bolt-Up Quote: send the joint list, location and test date
- Contact BoltUp Services

Get a quote on your bolt-up
Send the systems, joint count, sizes and ratings, location and test date. Henry Froats Jr., our Director, reviews every request and will tell you plainly what the job takes.
Ask for a demo of our digital joint records on your project discovery call.
- Over 10 years in the field through HydroTech Testing
- Recent bolt-up on an LNG vessel built in Philadelphia
- Hydro and nitrogen testing in-house through our sister companies
- Crews coast to coast across the USA, plus the UAE and Japan
