On-Site Flange Facing Services
A scratched or pitted flange face will leak no matter how carefully the bolts are tightened, and replacing the flange is rarely practical.
BoltUp Services provides on-site flange facing services that restore damaged sealing surfaces in place, so a joint can be made up and pass its test without cutting out the flange. Inspection sometimes finds a face that cannot seal as it is: a deep radial scratch, pitting, corrosion, a warped face or a damaged ring groove. On a vessel, in a pipe rack or in a crowded equipment room, removing that flange is slow and expensive.
- Over 10 years in the field through HydroTech Testing
- Recent bolt-up on an LNG vessel built in Philadelphia
- Hydro and nitrogen testing in-house through our sister companies
- Crews coast to coast across the USA, plus the UAE and Japan
How our on-site flange facing services work
1. Inspect and document. We record the damage, its location and depth, with photos for your QA team or engineer.
2. Confirm the finish. The required face finish and flatness come from the flange standard and your specification.
3. Set up the facer. A portable flange facing machine is mounted on the flange or bore, centered and leveled.
4. Machine the face. Light, controlled cuts remove the damage and restore the specified finish, keeping material removal to the minimum needed.
5. Verify. The finish and flatness are checked before the joint is released.
6. Re-make and test. The joint is made up with our standard bolt-up process and included in the follow-up hydrostatic or nitrogen test.
Faces we restore
- Raised-face flanges with damaged serrations or radial scratches
- Flat-face flanges on pumps, valves and equipment
- Ring-type joint (RTJ) grooves that are damaged or worn
- Heat exchanger, valve bonnet and manway sealing faces
- Flanges with corrosion or pitting on the gasket seating area
Want these joints made up right the first time? Send the joint list and test date, or call Henry Froats Jr., Director.
Why face it instead of forcing it
A damaged face rarely gets better with more bolt load. Over-tightening to force a seal can crush the gasket and overstress the studs, and the joint will often leak later anyway. Restoring the face once is faster than chasing the same leak through repeated tests.
Where flange facing comes up
Facing needs are common in turnarounds and outages where old flanges are opened after years in service, in ship repair where corrosion is a constant, and in new construction when spools are damaged in handling or storage. Because our bolting crew finds the damage during inspection, facing can happen immediately instead of waiting on another contractor.
Common questions
How much material does facing remove?
Only what is needed to remove the damage and restore the specified finish. If the remaining thickness would be a concern, we stop and raise it with your engineer before cutting further.
Can you face flanges on board a vessel?
Yes. Portable facers mount directly on the flange, so faces can be restored in machinery spaces and pipe passages without removing the spool.
When does a flange face need refacing?
When the sealing face has radial scratches across the serrations, pitting, corrosion, dents or erosion beyond the acceptance limits for the gasket type, or is out of flat. A face that fails inspection will not seal reliably with a new gasket alone.
Can you reuse a flange gasket?
No. Fit a new gasket every time a joint is opened. Gaskets seal by deforming once, and a used gasket can look fine while being hardened or relaxed. The one exception is grooved metal gaskets that are professionally refaced to the original specification.
Every Joint Documented. Nothing on Paper.
Our team uses modern AI tools to build interactive project management software for each job. Every joint, torque or tension value, gasket, inspection and test result is recorded and organized digitally, so you can find it by system, test package or joint number instead of digging through clipboards and paper tags.
- The status of every joint, visible as the work progresses
- Target values, tools, technician and date captured on each joint
- Inspection findings and test results linked to the joints they cover
- A clean, searchable turnover record when the job is done
Good records are how you know the work was done right. Ask for a demo on your project discovery call.
What to send for a fast quote
- Facility type and location
- Systems in scope and whether it is new construction, a shutdown or a retrofit
- Joint count by size and pressure class, or a line list or isometrics
- Gasket and fastener specs, plus any bolting procedure or torque tables
- Whether a hydrotest or nitrogen test follows, and the target dates
- Photos of the damaged faces, flange size and rating
Related Pages
- Ferry and Workboat Flange Bolt-Up in Puget Sound, WA
- Naval Shipbuilding Piping Bolt-Up in Pascagoula, MS
- Refinery Turnaround Controlled Bolting in Houston, TX
- Related service: Gasket Installation and Flange Face Inspection
- Request a Bolt-Up Quote: send the joint list, location and test date
- Contact BoltUp Services

Get a quote on your bolt-up
Send the systems, joint count, sizes and ratings, location and test date. Henry Froats Jr., our Director, reviews every request and will tell you plainly what the job takes.
Ask for a demo of our digital joint records on your project discovery call.
- Over 10 years in the field through HydroTech Testing
- Recent bolt-up on an LNG vessel built in Philadelphia
- Hydro and nitrogen testing in-house through our sister companies
- Crews coast to coast across the USA, plus the UAE and Japan
