Our Controlled Bolting Process

This is the BoltUp Services controlled bolting process. Good bolting is a process, not a heroic effort at the end of a job. Here is how BoltUp Services takes a project from first call to tested joints.

Our controlled bolting process, step by step

1. Scope call with Henry

It starts with a conversation. Henry Froats Jr., our Director, talks through your systems, joint count, schedule, access, specifications and whether testing will follow. Call 724-809-3385 or email info@hydrotechtesting.com.

2. Review specifications and drawings

We review line specifications, isometrics, P&IDs or system drawings and your bolting procedure. We confirm target values, gasket types, stud materials and the tightening method for each joint type, and raise questions early.

3. Build the joint register

Every joint in scope gets a number, a description and a status. Joints are grouped by system, test package or compartment so bolt-up follows the order your project needs.

4. Plan tools, crew and access

We select torque or tensioning tools for each joint size and access condition, plan low-clearance tooling for tight spaces, and size the crew to your schedule. Site safety requirements, permits and orientation are arranged before mobilization.

5. Inspect before assembly

Faces, gaskets, studs and nuts are checked. Problems are reported to your QA team before they become test failures.

6. Controlled tightening

Joints are aligned, lubricated and tightened in staged passes using a cross pattern, followed by check passes at the final value. See controlled bolting and tensioning.

7. Tag and record

Each completed joint is tagged and recorded with the values, tools, technician and date.

8. Test

When your project supports it, we coordinate hydrostatic testing through HydroTech Testing or nitrogen leak testing through NitroTech Rentals. If a joint weeps, the bolting crew is there to address it.

9. Turnover

The joint register and records are handed over with your test package so owners, class and QA have a complete history.

Related Pages

Send Us the Joint List and the Test Date

Projects in mind? Call Henry Froats Jr., our Director, directly to see what we can do for you. Tell us the systems, joint sizes and ratings, the location and when you need to test.

Email info@hydrotechtesting.com. Part of the same family of companies as HydroTech Testing and NitroTech Rentals.

Call Get a quote